# HP Smart Array CLI Commands #

HP Smart Array CLI commands


 


Show configuration


/opt/hp/hpssacli/bin/hpssacli ctrl all show config


 


Controller status


/opt/hp/hpssacli/bin/hpssacli ctrl all show status


 


Show detailed controller information


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail


 


Rescan for New Devices


/opt/hp/hpssacli/bin/hpssacli rescan


 


Physical disk status


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status


 


Show detailed physical disk information


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail


 


Logical disk status


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status


 


View Detailed Logical Drive Status


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show


 


Create New RAID 0 Logical Drive


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0


 


Create New RAID 1 Logical Drive


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1


 


Create New RAID 5 Logical Drive


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5


 


Delete Logical Drive


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete


 


Add New Physical Drive to Logical Volume


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7


 


Add Spare Disks


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7


 


Enable Cache


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable


 


Disable Cache


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable


 


Erase Physical Drive


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase


 


Turn on Blink Physical Disk LED


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on


 


Turn off Blink Physical Disk LED


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off


 


Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0


 


Disable smart array cache for certain Logical Volume


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable


 


Enable smart array cache for certain Logical Volume


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable


 


Enable SSD Smart Path==


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable


 


Disable SSD Smart Path


/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable


 


출처 URL : https://www.inetmail.ca/Wiki/index.php/HP_Smart_Array_CLI_commands_on_ESXi#Controller_status